When you need to measure a voltage that sits on a different ground than your ADC — say, monitoring a high-side current shunt on a 400V motor drive, or recording ECG signals from a patient — you can't just wire it directly. Common-mode voltages will destroy your op-amp, and ground loops will inject 60 Hz hum into your measurement. The fix is an isolation amplifier: a device that transfers analog signals across a barrier with no ohmic connection.
There are three common isolation mechanisms:
The critical specs to understand:
Real-world example: motor current sensing. Put a 5 mΩ shunt in the low-side of a 100A motor drive. The shunt sits on a switching node that bounces between 0V and 400V at 20 kHz. Wire the shunt across an AMC1300's ±250 mV input. The chip outputs a differential signal (Vref ± gain × Vin) referenced to the clean MCU side. Now your ADC sees a quiet 0-3.3V signal isolated from the killer transients.
Power isolation matters too. The "hot" side needs its own supply. Either use a tiny isolated DC-DC converter (e.g., Murata MEU1), or pick an integrated solution like the AMC1300 + ISOW7841 combo that bundles signal and power isolation in one package.
Rule of thumb for working voltage derating: Take the datasheet VIOWM and divide by 2 for design margin. A "1500V" part is really good for ~750V continuous in a noisy environment. Always verify the safety standard (UL 1577, IEC 60747-17 reinforced) matches your application's certification needs.